Model 5002 – Legacy

We will no longer be able to replace displays on the 5002. If you are in need a new display for this model, EMS can only offer a 5003 display upgrade. Contact us for pricing.

This filter has been discontinued.

Upgrade to the EMS Filter System.

Product Specifications

Power: 10 -16 VDC (110/220 VAC 50/60 Hz optional)
Ranges: HC: 0 – 2000 ppm Low Range
HC: 0-20,000 ppm High Range
CO: 0 – 10%
CO2: 0 – 20%
O2: 0 – 25%
NO: 0 – 5000 ppm (Nitric Oxide)*
Warmup: Less than 5 minutes
Display Resolution: HC: 1 ppm vol.
CO: 0.01% vol.
CO2: 0.1% vol.
O2: 0.01% vol.
NO: 1ppm*
Digital Display: 3” x 5” LCD Displays all 5 gases, & AFR or LAMDA
Accuracy (BAR 97 EPA ASM) HC: 4 ppm HC
CO: 0.06% CO
CO2: 0.3% CO2
O2: 0.1% O2
NO: 25 ppm*
Drift: Zero and span drift are less than ± 0.6% of full scale for the first hour and less than ± 0.4% of full scale per hour thereafter.
System Response Time: Bench: 1.5 Sec/25 ft. hose 5 sec. to 90% of final reading
Ambient Conditions: 35F (2C) to 120F (45C), rel. humidity 0-98%
Sample Hose: 25 feet ( 7.5 m) with QD coupling /200 F Degrees Max.
Sample Probe: Stainless steel 1200 Degrees F (replaceable flex tip)
Mass: Approx.: 10 LBS. (4.5 Kg)

Diagnostic Articles using EMS Emissions Gas Analyzers

Go to Top